SystemTest PM, 25-3-2004 ------------------------ DH, private notes Plans for Marseille (DH): - burn in -30..+30 as soon as chiller arrives, with fluorohexane C6F14 >> Maurice mentions that a test with LBL in an unsealed chiller >> resulted in evaporation of half of the liquid within one week!!! >> Sealing seems to be indispensable, if economic use of resources. - module position measurements before and after bonding the pigtails >> Eric should have received an email from Walter - regulator board back to Milano with Attilio (having applied 9V to regulator input, max. 7V allowed) - DCS operated, tested, feedback sent to Wuppertal and got positive response >> Fabian reminds Marseille to send the list of "needed material" I mentioned that PP0 cables are missing. ROD based multi-module readout: - ready to perform a scan - problem: digital injection fine, analog injection fine for low V_cal, but oscillation close to a threshold! >> Kevin suspects grounding problem. LBL projects (KE): - upgrading to readout of 2 sectors BN projects (FH): - shipping modules to CPPM for loading ------------------------------------- PRE-phone call with Jojo Schultes - ini function for startup PVSS => also wants my H1-recipe how to start automatically - shutdown-function (HV off? dialog) - LED in ISEG-Module for 16-fold OR "HV on" - 4mA is maximum. Goes into current control then, doesn't cut power any more - stave exchange (production): unique datapoings, with additional archiving information. Solution under study.